RKI AirLink T3A Wireless Gas Detector, 3-Wire Power (each)
Airlink T3A Wireless Monitor
Explosion Proof Transmitter
• Explosion Proof, Class I, Division 1 for CO, H2S, O2, LEL, & CO2
• Class I, Division 2 for all other gases
Features
- Electrochemical, Infrared, catalytic bead sensor element
-
Wire powered (3-Wire), 12 to 35 VDC operating voltage
-
Output options:
Wireless 900 MHz or 2.4 GHz
4-20mA (3-wire) analog
RS-485 modbus -
Digital Modbus output
-
Operating temperature range -40°C to +54°C
-
Graphical LCD with LED backlight
-
3 Push-button interface (ADD, MENU, SUB) with 3 corresponding magnetic, non-intrusive switches
-
2 Individually configurable alarms
-
2 Front panel LED indicators (amber and red)
-
2 Optional fully programmable alarm relays (dry contacts)
Description
The AirLink T3A Series Gas Detector ambient air hazardous gas detector is a versatile assembly that uses an electrochemical, infrared, catalytic bead sensor element to detect a variety of gases. Wired power (12 to 35 VDC) with wireless communication controller. An RKI wireless T3A also has 4-20 mA analog and RS-485 Modbus outputs as standard. Magnetic switches allow for non-intrusive calibration while in the field as well as full system settings and diagnostics.
The Airlink T3A represents the latest leading edge technology in fixed gas detection today.
Specifications
Sensor Type | Electrochemical, infrared, catalytic bead | |
Operating Voltage | Wired power (3-Wire) 12 to 35 VDC | |
Power Draw | 2 Watts maximum | |
Protection | Power electromagnetic interference (EMI) filter
4-20 mA surge suppression RS-485 surge suppression |
|
Display Screen | 102×64 Resolution graphical LCD screen transflective (sunlight readable) with white LED backlight | |
Interface | 3 Push-buttons (MENU, ADD and SUB)
3 Magnetic non-intrusive switches for calibration |
|
Customizable Settings | 2 Individual-configurable alarm LED/relay set-points | |
Temperature Range | -40°C to +54°C (-40°F to +130°F) | |
Wireless Output, Radio Options | 900 MHz (200 mW) radio (1-1.5 miles range) or 2.4 GHz (125 mW) radio (1-1.5 miles range) |
|
Networks | 52 Networks (900 MHz radio) or 78 networks (2.4 GHz radio)
255 addresses per network |
|
Output (digital) | RS-485 modbus | |
Wired (Analog) Output | 4-20 mA (3-Wire)
Fault terminal Optional 2 dry-contact relays with replaceable 4 amp fuses |
|
Remote Sensor Kit
(Optional Additional Feature) |
Remote sensor kit with enclosure (5 pin)
• Electrochemical sensor max. length: 250 feet • Infrared sensor max. length: 40 feet • Catalytic bead sensor max. length: 15 feet |
|
Product Dimensions | 5.5 in, L x 6 in. D x 7 in. H (8 in. W x 17 in. H Max. dimensions with attachments) | |
Total Weight | 6 lbs. | |
Hazardous Location
Approvals |
Main Enclosure | Certified explosion / flame proof CQPSUS
Class I, Division 1 & 2, Groups B, C & D Nema 3, 4, 4X, 7 (B, C, D) 9 (E, F, G) Temp.= -20°C to +60°C |
Sensor Housing | Certified explosion / flame proof CQPSUS
Class I, Division 1 & 2, Groups B, C & D Temp.= -40°C to +60°C Note: Certification only applies to some gases. Toxic gases not certified for Div. 1 locations are suitable for Div. 2 applications but have no third party approval. |
|
Controllers, Wireless | Compatible with AirLink 7010 and AirLink 7032 | |
Controllers, Analog | Compatible with all RKI Beacon controllers, as well as most DCS / PLC systems: Beacon 110, Beacon 200, Beacon 410A and Beacon 800, and MC-6400 | |
Warranty | 1-Year warranty for electronics and sensor |